Mitsubishi Electric MSZ-EF42VES Wartungshandbuch

Stöbern Sie online oder laden Sie Wartungshandbuch nach Split-System-Klimaanlagen Mitsubishi Electric MSZ-EF42VES herunter. Mitsubishi Electric MSZ-EF42VES Service manual [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
CONTENTS
1. TECHNICAL CHANGES ··································· 3
2. PART NAMES AND FUNCTIONS ····················· 4
3. SPECIFICATION ················································ 5
4. NOISE CRITERIA CURVES ······························ 6
5. OUTLINES AND DIMENSIONS ························ 8
6. WIRING DIAGRAM ············································ 9
7. REFRIGERANT SYSTEM DIAGRAM ··············· 9
8. SERVICE FUNCTIONS ··································· 10
9. MICROPROCESSOR CONTROL ··················· 12
10. TROUBLESHOOTING ····································· 18
11. DISASSEMBLY INSTRUCTIONS ···················· 31
SPLIT-TYPE AIR CONDITIONERS
SERVICE MANUAL
No. OBH589
REVISED EDITION-A
INDOOR UNIT
PARTS CATALOG (OBB589)
NOTE:
RoHS compliant products have <G> mark on the spec name plate.
Models
MSZ-EF22VEW -
E1
MSZ-EF22VEB -
E1
MSZ-EF22VES -
E1
MSZ-EF25VEW -
E1
MSZ-EF25VEB -
E1
MSZ-EF25VES -
E1
MSZ-EF35VEW -
E1
MSZ-EF35VEB -
E1
MSZ-EF35VES -
E1
MSZ-EF42VEW -
E1
MSZ-EF42VEB -
E1
MSZ-EF42VES -
E1
MSZ-EF50VEW -
E1
MSZ-EF50VEB -
E1
MSZ-EF50VES -
E1
Models
MSZ-EF22VEW -
E1
MSZ-EF25VEW -
E1
MSZ-EF35VEW -
E1
MSZ-EF42VEW -
E1
MSZ-EF50VEW -
E1
MSZ-EF22VEB -
E1
MSZ-EF25VEB -
E1
MSZ-EF35VEB -
E1
MSZ-EF42VEB -
E1
MSZ-EF50VEB -
E1
MSZ-EF22VES -
E1
MSZ-EF25VES -
E1
MSZ-EF35VES -
E1
MSZ-EF42VES -
E1
MSZ-EF50VES -
E1
Outdoor unit service manual
MUZ-EF·VE(H) Series (OBH590)
MXZ-C·VA Series (OB584)
Please void OBH589.
Revision A:
Airflow in the Silent mode in the cooling
operation has been changed.
• "
TROUBLESHOOTING" has been corrected.
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - SERVICE MANUAL

CONTENTS1. TECHNICAL CHANGES ··································· 32. PART NAMES AND FUNCTIONS ····················· 43. SPECIFICATION ················

Seite 2 - Revision A:

108-1. TIMER SHORT MODEFor service, set time can be shortened by short circuit of JPG and JPS on the electronic control P.C. board.The time will be sh

Seite 3 - TECHNICAL CHANGES

118-3. AUTO RESTART FUNCTIONWhen the indoor unit is controlled with the remote controller, the operation mode, the set temperature, and the fan speed

Seite 4 - PART NAMES AND FUNCTIONS

12WIRELESS REMOTE CONTROLLERMSZ-EF22VEW MSZ-EF25VEW MSZ-EF35VEW MSZ-EF42VEW MSZ-EF50VEWMSZ-EF22VEB MSZ-EF25VEB MSZ-EF35VEB MSZ-EF42VEB MSZ-EF50VEBMSZ-

Seite 5 - SPECIFICATION

139-2. DRY ( ) OPERATION(1) Press OPERATE/STOP (ON/OFF) button.OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.(2) Select DRY mo

Seite 6 - NOISE CRITERIA CURVES

14NOTE 2 FOR MULTI SYSTEM AIR CONDITIONER OUTDOOR UNIT: MXZ series Multi system air conditioner can connect two or more indoor units with one outdoo

Seite 7

159-7. TIMER OPERATION1. How to set the time (1) Check that the current time is set correctly.NOTE: Timer operation will not work without setting the

Seite 8 - OUTLINES AND DIMENSIONS

169-8. WEEKLY TIMER OPERATION• A maximum of 4 ON or OFF timers can be set for individual days of the week.• A maximum of 28 ON or OFF timers can be se

Seite 9 - REFRIGERANT SYSTEM DIAGRAM

17(5) Press button to turn the weekly timer ON. ( lights.)•When the weekly timer is ON, the day of the week whose timer setting is complete, will

Seite 10 - SERVICE FUNCTIONS

1810-1. CAUTIONS ON TROUBLESHOOTING1. Before troubleshooting, check the following1) Check the power supply voltage.2) Check the indoor/outdoor connect

Seite 11 - Indoor electronic

1910-2. FAILURE MODE RECALL FUNCTIONOutline of the functionThis air conditioner can memorize the abnormal condition which has occurred once.Even thoug

Seite 12 - MICROPROCESSOR CONTROL

2<Preparation before the repair service> Prepare the proper tools. Prepare the proper protectors. Provide adequate ventilation. After stoppi

Seite 13 - 9-4. HEAT ( ) OPERATION

202. Indoor unit failure mode tableThe left lamp of OPERATION INDI-CATOR lampAbnormal point (Failure mode) Condition RemedyNot lighted Normal — —1-t

Seite 14 - Horizontal

2110-3. INSTRUCTION OF TROUBLESHOOTINGIndoor unit oper-ates.Outdoor unit does not operate.If blinking of OPERATION INDI-CATOR lamp cannot be checked,

Seite 15 - PROGRAM TIMER

2210-4. TROUBLESHOOTING CHECK TABLEBefore taking measures, make sure that the symptom reappears for accurate troubleshooting.When the indoor unit has

Seite 16 - 9-8. WEEKLY TIMER OPERATION

23OPERATION INDICATOR No. Abnormal point Operation indicator lamp Symptom Condition Remedy 1MXZ type Operation mode settingLeft lamp lights and

Seite 17 - (E.O. SW)

24 A Check of indoor fan motor10-6. TROUBLESHOOTING FLOWThe indoor fan motor error has occurred, and the indoor fan does not operate.Turn OFF the po

Seite 18 - TROUBLESHOOTING

25 B Check of remote controller and indoor electronic control P.C. board Check if the remote controller is exclusive for this air conditioner.Does th

Seite 19

26 C Check of indoor P.C. board and indoor fan motorTurn OFF the power supply.Remove indoor fan motor connector CN211 from indoor power P.C. board a

Seite 20

27 D How to check miswiring and serial signal errorMUZ-EF TypeTurn OFF inverter-controlled lighting equipment.Turn OFF the power supply and then turn

Seite 21

28Turn OFF inverter-controlled lighting equipment.Turn OFF the power supply and then turn ON again.Press EMERGENCY OPERATION switch.•••AIs serial sign

Seite 22

29 E Electromagnetic noise enters into TV sets or radiosYesIs the unit earthed?NoEarth the unit.YesIs the distance between the antennas and the indoo

Seite 23 - (Temperature: 10 - 30°C)

3TECHNICAL CHANGES1MSZ-EF22VEW - E1MSZ-EF25VEW - E1MSZ-EF35VEW - E1MSZ-EF42VEW - E1MSZ-EF50VEW - E1MSZ-EF22VEB - E1MSZ-EF25VEB - E1MSZ-EF35VEB - E1MSZ

Seite 24 - A Check of indoor fan motor

30Room temperature thermistor (RT11)Indoor coil thermistor (RT12, RT13)Temperature (°C)Resistance (kΩ)Indoor electronic control P.C. boardIndoor power

Seite 25

31MSZ-EF22VEW MSZ-EF25VEW MSZ-EF35VEW MSZ-EF42VEW MSZ-EF50VEWMSZ-EF22VEB MSZ-EF25VEB MSZ-EF35VEB MSZ-EF42VEB MSZ-EF50VEBMSZ-EF22VES MSZ-EF25VES MSZ-EF

Seite 26 - P.C. board

32OPERATING PROCEDURE PHOTOS2. Remove the indoor electrical box(1) Remove the panel (Refer to 1.) and the corner box right.(2) Remove the screw of the

Seite 27 - MUZ-EF Type

33OPERATING PROCEDURE PHOTOS4. Removing the nozzle assembly(1) Remove the panel (Refer to 1.) and the corner box right.(2) Remove the indoor/outdoor c

Seite 28 - MXZ Type

34OPERATING PROCEDURE PHOTOS6. Removing the indoor fan motor, the indoor coil thermistor and the line flow fan(1) Remove the panel (Refer to 1.) and t

Seite 30 - Resistance (kΩ)

HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN© Copyright 2010 MITSUBISHI ELECTRIC CO., LTDDistributed in Mar. 2011.

Seite 31 - DISASSEMBLY INSTRUCTIONS

4ACCESSORIESMSZ-EF22VEW MSZ-EF25VEW MSZ-EF35VEW MSZ-EF42VEW MSZ-EF50VEWMSZ-EF22VEB MSZ-EF25VEB MSZ-EF35VEB MSZ-EF42VEB MSZ-EF50VEBMSZ-EF22VES MSZ-EF25

Seite 32 - OPERATING PROCEDURE PHOTOS

5Indoor modelMSZ-EF22VEWMSZ-EF22VEBMSZ-EF22VESMSZ-EF25VEWMSZ-EF25VEBMSZ-EF25VESMSZ-EF35VEWMSZ-EF35VEBMSZ-EF35VESMSZ-EF42VEWMSZ-EF42VEBMSZ-EF42VESMSZ-E

Seite 33

6MSZ-EF22VEW MSZ-EF25VEWMSZ-EF22VEB MSZ-EF25VEBMSZ-EF22VES MSZ-EF25VES90807060504030201063 125 250 500 1000 2000 4000 8000NC-60NC-50NC-40NC-30NC-20NC-

Seite 34

7Test conditionsCooling: Dry-bulb temperature 27 °CWet-bulb temperature 19 °CHeating: Dry-bulb temperature 20 °CINDOOR UNITWALLMICROPHONE0.8m1mMSZ-EF4

Seite 35

8Unit: mmMSZ-EF22VEW MSZ-EF25VEW MSZ-EF35VEW MSZ-EF42VEW MSZ-EF50VEWMSZ-EF22VEB MSZ-EF25VEB MSZ-EF35VEB MSZ-EF42VEB MSZ-EF50VEBMSZ-EF22VES MSZ-EF25VES

Seite 36

9MSZ-EF22VEW MSZ-EF25VEW MSZ-EF35VEW MSZ-EF42VEW MSZ-EF50VEWMSZ-EF22VEB MSZ-EF25VEB MSZ-EF35VEB MSZ-EF42VEB MSZ-EF50VEBMSZ-EF22VES MSZ-EF25VES MSZ-EF3

Kommentare zu diesen Handbüchern

Keine Kommentare