CONTENTS
1.TECHNICAL CHANGES ·····································2
2. PART NAMES AND FUNCTIONS······················2
3. SPECIFICATION·················································4
4. NOISE CRITERIA CURVES·······························6
5. OUTLINES AND DIMENSIONS ·························7
6. WIRING DIAGRAM ············································8
7. REFRIGERANT SYSTEM DIAGRAM················8
8. PERFORMANCE CURVES································9
9. SERVICE FUNCTIONS ····································19
10. TROUBLESHOOTING······································21
11. DISASSEMBLY INSTRUCTIONS·····················35
12. PARTS LIST······················································39
13. RoHS PARTS LIST···········································43
14. OPTIONAL PARTS···········································47
MFZ-KA25VA -
MFZ-KA25VA -
MFZ-KA35VA -
MFZ-KA35VA -
MFZ-KA50VA -
MFZ-KA50VA -
A2
A1
A2
A1
A2
A1
FLOOR-TYPE, HEAT PUMP AIR CONDITIONERS
MFZ-KA25VA
MFZ-KA35VA
MFZ-KA50VA
NOTE:
• This service manual describes technical data of the indoor units.
• RoHS compliant products have <G> mark on the spec name plate.
For servicing of RoHS compliant products, refer to the RoHS Parts List.
SERVICE MANUAL
Wireless type
Models
No. OB410
REVISED EDITION-A
INDOOR UNIT
Revision A:
MFZ-KA25VA- , MFZ-KA35VA- and
MFZ-KA50VA- have been added.
“Failure mode recall function” has been corrected.
RoHS PARTS LIST has been added.
A2
A2A2
Please void OB410.
Outdoor unit service manual
SUZ-KA•VA Series (OC323)
MXZ-A•VA Series (OB447, OC316)
OB410A--1qxp 06.6.2 4:25 PM Page 1
Seitenansicht 0
1 2 3 4 5 6 ... 47 48

Inhaltsverzeichnis

Seite 1 - INDOOR UNIT

CONTENTS1.TECHNICAL CHANGES ·····································22. PART NAMES AND FUNCTIONS······················23. SPECIFICATION··················

Seite 2 - PART NAMES AND FUNCTIONS

10OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENT24.422.620.718.816.915.013.211.327.525.423.321.219.116.914.812.7Indoor air Dry-bulb temperaturedifferen

Seite 3 - MFZ-KA50VA

11Outdoor unit current(A)3218Ambient temperature(˚C) Ambient humidity(%)SUZ-KA35VA.THOutdoor unit current(A)Ambient temperature(˚C) Ambient humidity(%

Seite 4 - SPECIFICATION

1221 18 2.94 1.41 0.48 464 2.81 1.35 0.48 487 2.70 1.30 0.48 510 2.60 1.25 0.48 53421 20 3.06 1.10 0.36 487 2.94 1.06 0.36 516 2.85 1.03 0.36 528 2.75

Seite 5

1321 18 2.45 1.18 0.48 568 2.25 1.08 0.48 603 2.08 1.00 0.48 62621 20 2.58 0.93 0.36 592 2.40 0.86 0.36 621 2.23 0.80 0.36 65522 18 2.45 1.27 0.52 568

Seite 6 - NOISE CRITERIA CURVES

1421 18 4.11 1.93 0.47 872 3.94 1.85 0.47 916 3.78 1.78 0.47 959 3.64 1.71 0.47 100321 20 4.29 1.50 0.35 916 4.11 1.44 0.35 970 3.99 1.40 0.35 992 3.8

Seite 7 - OUTLINES AND DIMENSIONS

1521 18 3.43 1.61 0.47 1068 3.15 1.48 0.47 1134 2.91 1.37 0.47 117721 20 3.61 1.26 0.35 1112 3.36 1.18 0.35 1166 3.12 1.09 0.35 123222 18 3.43 1.75 0.

Seite 8 - REFRIGERANT SYSTEM DIAGRAM

1621 18 5.64 2.54 0.45 1240 5.40 2.43 0.45 1302 5.18 2.33 0.45 1364 4.99 2.25 0.45 142621 20 5.88 1.94 0.33 1302 5.64 1.86 0.33 1380 5.47 1.81 0.33 14

Seite 9 - PERFORMANCE CURVES

1721 18 4.70 2.12 0.45 1519 4.32 1.94 0.45 1612 3.98 1.79 0.45 167421 20 4.94 1.63 0.33 1581 4.61 1.52 0.33 1659 4.27 1.41 0.33 175222 18 4.70 2.30 0.

Seite 10 - SUZ-KA25VA.TH

18INDOOR-10Q INPUT-5Q INPUT0Q INPUT5Q INPUT10Q INPUT15Q INPUT20Q INPUT1521262.142.041.845345856262.582.452.286516937353.032.892.697358688103.473.303.1

Seite 11 - HEATING operation

19SERVICE FUNCTIONS99-1. TIMER SHORT MODEFor service, set time can be shortened by short circuit of JPG and JPS on the electronic control P.C. board.T

Seite 12 - MFZ-KA25VA/ SUZ-KA25VA.TH

21TECHNICAL CHANGES2PART NAMES AND FUNCTIONSINDOOR UNITMFZ-KA25VAMFZ-KA35VAMFZ-KA50VAVertical vaneAir outletHorizontal vaneCatechin air filterDisplay

Seite 13

20NOTE:• The operation settings are memorized when 10 seconds have passed after the indoor unit was operated with the remotecontroller.• If main power

Seite 14 - MFZ-KA35VA/ SUZ-KA35VA.TH

21TROUBLESHOOTING1010-1. Cautions on troubleshooting1. Before troubleshooting, check the following:1) Check the power supply voltage.2) Check the indo

Seite 15

22Outline of the functionThis air conditioner can memorize the abnormal condition which has occurred once.Even though OPERATION INDICATOR lamp indicat

Seite 16 - MFZ-KA50VA/ SUZ-KA50VA.TH

232. Indoor unit failure mode tableNOTE:Blinking patterns of this mode differs from the ones of Troubleshooting check table (10-4.). 12-time flash2.5-

Seite 17

24StartIndoor unit operates.Outdoor unit doesn't operate.Indoor unit doesn't receive the signal from remote controller.OPERATION INDICATORl

Seite 18

25NOTE : When the indoor unit has started operation and the above failures are detected (the first detection after the power ON), the indoor electr

Seite 19 - SERVICE FUNCTIONS

2610-5. Trouble judgement criteria of main partsMFZ-KA25VA MFZ-KA35VA MFZ-KA50VAPart name FigureCheck method and criteriaIndoor fan motor (Upper)(MF1)

Seite 20

27-1. Check of indoor fan motor (upper)AWhen the left lamp of OPERATION INDICATOR lamp flashes 3 times and the right lamp of OPERATION INDICATOR lamp

Seite 21 - Lead wiring

28-2. Check of indoor fan motor (lower)AWhen the left lamp of OPERATION INDICATOR lamp flashes 3 times and the right lamp of OPERATION INDICATOR lamp

Seite 22

29Check of remote controller and receiver P.C. board BIndoor unit operates by pressing EMERGENCY OPERATION switch, but does not operate with the remot

Seite 23

3ACCESSORIESREMOTE CONTROLLER1234567890123Drain hoseRemote controller holderFixing screw for 2 3.5 o 1.6 mm (Black)Pipe coverBandBattery (AAA) for rem

Seite 24

30The unit cannot be operated with the remote controller.Also, OPERATION INDICATOR lamp does not light up by pressing EMERGENCY OPERATION switch.Check

Seite 25 - Blinking

31How to check mis-wiring and serial signal errorDWhen the left lamp of OPERATION INDICATOR lamp flashes ON and OFF in every 0.5-second.Outdoor unit d

Seite 26

32Check of damperEWhen the left lamp of OPERATION INDICATOR lamp flashes 15-time. Indoor unit and outdoor unit do not operate.Turn OFF the power suppl

Seite 27 - 10-6. Troubleshooting flow

33Electromagnetic noise enters into TV sets or radiosFNoNoNoYesYesNoNoYesYesYesIs the distance between theantennas and the indoorunit within 3m, or is

Seite 28 - Indoor fan does not operate

34Indoor coil thermistor [RT12,RT14,RT15 (MAIN), RT13 (SUB)] Room temperature thermistor (RT11)Temperature (:)Resistance (k")MFZ-KA25VA MFZ-KA35V

Seite 29

35DISASSEMBLY INSTRUCTIONS11(1) Slide the sleeve and check if there is a locking lever or not. (2) The terminal with this connector has the loc

Seite 30 - Indoor electronic

362. Removing the electronic control P.C. board and thedisplay receiver P.C. board(1) Remove the panel. (Refer to 1.)(2) Remove the screw of the elec

Seite 31

37OPERATING PROCEDURE PHOTOSPhoto 74. Removing the horizontal vane motor unit(1) Remove the panel. (Refer to 1.)(2) Remove the screws of the horizonta

Seite 32 - Check of damper

38OPERATING PROCEDURE PHOTOSPhoto 11Photo 13Photo 10Photo 12Screws of the damper lock motor (Right)Screws of thedamper motorLead wires of the damper m

Seite 33

39PARTS LIST (non-RoHS compliant)12MFZ-KA25VAMFZ-KA35VAMFZ-KA50VA12-1. INDOOR UNIT STRUCTURAL PARTSNo.Part No.Part nameRemarksSymbolin WiringDiagramQ&

Seite 34

43SPECIFICATIONCooling522426/ 348/ 288 1,080940/ 800/ 700880 740/ 650/ 550MFZ-KA35VAMFZ-KA25VA MFZ-KA50VA Indoor modelFunctionPower supplySingle pha

Seite 35 - Locking lever

4012-3. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTSMFZ-KA25VAMFZ-KA35VAMFZ-KA50VA123456714 15 12 191618242123 228912131011172526201815PARTS LIST

Seite 36 - OPERATING PROCEDURE PHOTOS

41NOZZLE ASSEMBLY (UPPER)HORIZONTAL VANE (BACK)HORIZONTAL VANE (FRONT)VANE SLEEVEBEARING ASSEMBLYNOZZLE ASSEMBLY (LOWER)DAMPER MOTORVANE MOTOR SUPPORT

Seite 37

42MFZ-KA25VAMFZ-KA35VAMFZ-KA50VA512-4. INDOOR UNIT HEAT EXCHANGER2341HAIR PIN COVERINDOOR HEAT EXCHANGERINDOOR HEAT EXCHANGERUNION (LIQ) UNION (GAS) U

Seite 38

43RoHS PARTS LIST (RoHS compliant)13MFZ-KA25VAMFZ-KA35VAMFZ-KA50VA13-1. INDOOR UNIT STRUCTURAL PARTSNo.RoHSPart No.Part nameRemarksSymbolin WiringDia

Seite 39 - A1 A1 A1

4413-3. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTSMFZ-KA25VAMFZ-KA35VAMFZ-KA50VA123456714 15 12 191618242123 228912131011172526201815RoHS PARTS

Seite 40

45NOZZLE ASSEMBLY (UPPER)HORIZONTAL VANE (BACK)HORIZONTAL VANE (FRONT)VANE SLEEVEBEARING ASSEMBLYNOZZLE ASSEMBLY (LOWER)DAMPER MOTORVANE MOTOR SUPPORT

Seite 41

46MFZ-KA25VAMFZ-KA35VAMFZ-KA50VA513-4. INDOOR UNIT HEAT EXCHANGER2341HAIR PIN COVERINDOOR HEAT EXCHANGERINDOOR HEAT EXCHANGERUNION (LIQ) UNION (GAS) U

Seite 42

47OPTIONAL PARTS14ModelPart No.A1A2MAC-415FT-EMFZ-KA25VA-MFZ-KA25VA-MFZ-KA35VA-MFZ-KA35VA-MFZ-KA50VA-MFZ-KA50VA-A1A2A2A1Replacement of the air cleanin

Seite 43 - A1 A2 A1 A2 A1 A2

HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO100-8310, JAPANCCCopyright 2005 MITSUBISHI ELECTRIC ENGINEERING CO.,LTDDistributed in Ju

Seite 44

5T3.15AL 250V12V 300"12V 300"12V 300"12V 300"ERZV14D471ItemModelFuse Damper lock motor RightDamper lock motor LeftHorizontal vane

Seite 45

64NOISE CRITERIA CURVESOCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 20 µPaOCTAVE BAND SOUND PRESSURE LEVEL, 0dB = 20 µPaOCTAVE BAND SOUND PRESSURE LEVEL, 0

Seite 46

7OUTLINES AND DIMENSIONS5Unit : mmINDOOR UNIT60121960125147454155603545110806072337 33736333321059371311314-[6 HoleIndoor unitInstallation plate961231

Seite 47 - OPTIONAL PARTS

86WIRING DIAGRAMREFRIGERANT SYSTEM DIAGRAM7IndoorheatexchangerFlared connectionRoom temperaturethermistorRT11Indoor coil thermistorRT12, RT14,RT15 (ma

Seite 48

9PERFORMANCE CURVES8Wet-and dry-bulbthermometersBACK VIEWOUTDOOR UNITFRONT VIEWWet and dry-bulbthermometersIndoor air Wet-bulb temperaturedifference (