Ethernet course(Q-series)
Mitsubishi Programmable Logic Controller Training Manual
Ethernet course(Q-series)
Ethernet course(Q-series)
Mitsubishi Programmable
Logic Controller
Training Manual
MODEL
MODEL
CODE
SCHOOL-Q-ETHERNET-E
13JW51
SH(NA)-080618ENG-A(0601)MEE
Specifications subject to change without notice.
When exported from Japan, this manual does not require application to the
Ministry of Economy, Trade and Industry for service transaction permission.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14 , YADA-MINAMI 5-CHOME , HIGASHI-KU, NAGOYA , JAPAN
Seitenansicht 0
1 2 3 4 5 6 ... 227 228

Inhaltsverzeichnis

Seite 1 - Ethernet course(Q-series)

Ethernet course(Q-series)Mitsubishi Programmable Logic Controller Training ManualEthernet course(Q-series)Ethernet course(Q-series)Mitsubishi Program

Seite 2

A - 8 MEMO

Seite 3 - SAFETY PRECAUTIONS

5 - 32 (1) Flowchart (a) cmdOpen_Click() (Operation by clicking the Open button) Refer to Section 5.4.1 (1) (a). (b) cmdOpen_Click() (Operation

Seite 4 - REVISIONS

5 - 33 (e) lblON_OFF_DblClick() (Operation when double-clicking a label) STARTENDYesNoDisplay of labelChange to " "Is the display of labe

Seite 5

5 - 34 5.5.2 Operation of demonstration machine The program is executed, and the device value of the PLC CPU is changed. (1) Program screen The fol

Seite 6

5 - 35 Continued from the previous page 4) Click the Open button to open the communication line. When opening normally, "Communication line

Seite 7

5 - 36 Continued from the previous page 9) Check the written numerical value in the MX Component. (*1) Refer to Section 5.4.2 (3), start up &qu

Seite 8

5 - 37 Continued from the previous page 13) Click the Exit button to complete the program. Reading the following project file is enabled. *1

Seite 9

5 - 38 MEMO

Seite 10

6 - 1 CHAPTER 6 ASSIGNMENT II (FIXED BUFFER COMMUNICATION BETWEEN PLC CPUS (PROCEDURE EXIST)) In this assignment, the exercise of the fixed buffer co

Seite 11 - Maximum

6 - 2 (2) Exercise description Display the information about X0 to X7 and about X20 to X2F of the PLC CPU on the sending side on Y70 to Y77 and Y40 t

Seite 12 - Destination

6 - 3 6.2 Ethernet Module Settings on the Sending Side The Ethernet module settings on the sending side are performed. 6.2.1 Setting parameters wi

Seite 13 - Host part(8)

1 - 1 Chapter 1 BASICS OF ETHERNET NETWORK Note This textbook mainly describes how to use MELSEC-Q Series Ethernet module. For details of general c

Seite 14 - 1111 1111 000000

6 - 4 Continued from the previous page 4) Set the following contents of the Network parameters Setting the number of MNET/10H Ethernet cards scr

Seite 15

6 - 5 Continued from the previous page 9) Click the Endbutton to close the Network parameter Ethernet open settings screen. 10) Click the End

Seite 16 - Selection of paths

6 - 6 6.2.2 Sequence program Create a sequence program to send data to the PLC CPU on the receiving side. Perform the open processing for the connect

Seite 17

6 - 7 (2) Sequence program For details on dedicated instructions, refer to Chapter 10 of Q Corresponding Ethernet Interface Module User's Manual

Seite 18 - IP network1 1-11-2

6 - 8 Send completionSend error completionSend error completionError LED offError clear switchCOM. ERR LED on confirmationCOM. ERR LED off requestCOM

Seite 19 - Application program E

6 - 9 6.3 Ethernet Module Settings on the Receiving Side The Ethernet module settings on the receiving side are performed. 6.3.1 Setting parameter

Seite 20

6 - 10 Continued from the previous page 4) Set the following contents of the Network parameters Setting the number of MNET/10H Ethernet cards sc

Seite 21

6 - 11 Continued from the previous page 9) Click the Endbutton to close the Network parameter Ethernet open settings screen. 10) Click the E

Seite 22

6 - 12 6.3.2 Sequence program Create a sequence program that performs the receive processing for the data sent from the external device. When the dat

Seite 23 - H to FFH can be processed

6 - 13 (2) Sequence program For details on dedicated instructions, refer to Chapter 10 of Q Corresponding Ethernet Interface Module User's Manua

Seite 24

1 - 2 1.2 Addresses The devices and computers connected to Ethernet must have their own addresses to communicate on the network. For Ethernet, the a

Seite 25

6 - 14 6.4 PING Test Using GX Developer (Via CPU) Execute the PING test using the GX Developer. The PING test is performed to check that the initial

Seite 26 - Supported

6 - 15 Continued from the previous page 4) Click the PING test button. 5) The PING test screen appears. Set as follows. Network No. : 1

Seite 27 - MELSECNET/H

6 - 16 REMARK The following example illustrates how to confirm the completion of the initial processing by issuing the PING command to the local stat

Seite 28 - Personal computer

6 - 17 6.5 Operation of Demonstration Machine Operate the demonstration machine to confirm that data is sent from the PLC CPU A (sending side) to th

Seite 29 - (Access station)

6 - 18 Continued from the previous page OFFX8ON 7) After the check on the I/O panel is completed, turn OFF "X8" of the PLC CPU A and co

Seite 30 - Data receiving

7 - 1 CHAPTER 7 ASSIGNMENT III (FIXED BUFFER COMMUNICATION BETWEEN PLC CPUS (NO PROCEDURE)) In this assignment, the exercise of fixed buffer communic

Seite 31 - PLC CPU (Access station)

7 - 2 (2) Exercise description Display the information about X0 to X7 and about X20 to X2F of the PLC CPU A on Y70 to 77 and Y40 to Y4F of the PLC CP

Seite 32

7 - 3 7.2 Ethernet Module Settings (PLC A1 to A5) The Ethernet module settings on PLC A1 to A5 side are performed. 7.2.1 Setting parameters with G

Seite 33 - GX Developer

7 - 4 Continued from the previous page 4) Set the following contents of the "Network parameters Setting the number of MNET/10H Ethernet card

Seite 34 - Ethernet module

7 - 5 Continued from the previous page 8) Set the following contents. Protocol : TCP Open system : Active Fixed buffer communication procedure

Seite 35

1 - 3 1.2.2 IP address The IP address (Internet Protocol Address) is an identification number assigned to identify each device or computer connected

Seite 36

7 - 6 7.2.2 Sequence program Create a sequence program. Perform the open processing (Paring open specification) for connection 1 and connection 2 wit

Seite 37

7 - 7 (1) List of devices to be used Device name Description Device name Description SM400 Normally ON X20 to X2F Data to be sent to the PLC C

Seite 38

7 - 8 (2) Sequence program For details on dedicated instructions, refer to Chapter 10 of Q Corresponding Ethernet Interface Module User's Manual

Seite 40

7 - 10

Seite 41 - H… b0) turns on and data

7 - 11 7.3 Ethernet Module Settings (PLC B1 to B5) The Ethernet module settings on the PLC B1 to B5 side are performed. 7.3.1 Setting parameters wi

Seite 42

7 - 12 Continued from the previous page 4) Set the following contents of the "Network parameters Setting the number of MNET/10H Ethernet

Seite 43 - (Active open acceptable)

7 - 13 Continued from the previous page 8) Set the following contents. Protocol : TCP Open system : Unpassive Fixed buffer communication p

Seite 44

7 - 14 7.3.2 Sequence program Create a sequence program. Establish a connection with Active open of the PLC CPUs on the A1 to A5 side, and then send

Seite 45 - H … b0): ON)

7 - 15 (1) List of devices to be used Device name Description Device name Description SM400 Normally ON Y40 to Y4F Stores the information of X2

Seite 46

1 - 4 The address management was once carried out in this class unit. Nowadays the class address with the variable-length border bit number is used f

Seite 47

7 - 16 (2) Sequence program For details on dedicated instructions, refer to Chapter 10 of Q Corresponding Ethernet Interface Module User's Manual

Seite 48

7 - 17

Seite 49

7 - 18 7.4 PING Test Using GX Developer (Via CPU) Execute the PING test using the GX Developer. The PING test is used to check that the initial proc

Seite 50

7 - 19 7.5 Operation of Demonstration Machine By operating the demonstration machine, confirm that data is sent and received between the PLC A and t

Seite 51

7 - 20 Continued from the previous page OFFX8ON 7) After checking the I/O panel is completed, turn OFF "X8" on the I/O panel on the se

Seite 52 - *1 The e-mail

8 - 1 CHAPTER 8 ASSIGNMENT IV (FIXED BUFFER COMMUNICATION BETWEEN PLC CPUS VIA ROUTER (NO PROCEDURE)) In this assignment, data communication via rout

Seite 53

8 - 2 8.2 Ethernet Module Settings (PLC A1 to A5) The Ethernet module settings on the PLC A1 to A5 side are performed. 8.2.1 Setting parameters wi

Seite 54

8 - 3 Continued from the previous page 4) Set the following contents of the "Network parameters Setting the number of MNET/10H Ethernet card

Seite 55

8 - 4 Continued from the previous page 8) Set the following contents. Protocol : TCP Open system : Active Fixed buffer communication procedu

Seite 56

8 - 5 Continued from the previous page 12) Click the End button to close the "Network parameters Setting the number of MNET/10H Ethernet

Seite 57

1 - 5 REMARK Special IP addresses (1) All bits are 0 or 1 The IP address 0.0.0.0 is used when you do not know your own IP address or it is not nece

Seite 58 - Twisted-pair cable

8 - 6 8.3 Ethernet Module Settings (PLC B1 to B5) The Ethernet module settings on the PLC B1 to B5 side are performed. 8.3.1 Setting parameters wi

Seite 59

8 - 7 Continued from the previous page 4) Set the following contents of the "Network parameters Setting the number of MNET/10H Ethernet car

Seite 60

8 - 8 Continued from the previous page 8) Set the following contents. Protocol : TCP Open system : Unpassive Fixed buffer communication proc

Seite 61

8 - 9 Continued from the previous page 13) Click the button. (Overwriting the project) 14) Set Drive/Path and Project name, then click the Sav

Seite 62

8 - 10 8.4 PING Test from Personal Computer The PING test is performed from the personal computer that executed the exercise of the MX Component to

Seite 63 - Target device 4

App - 1 APPENDIX Appendix 1 Visual Basic® Version 6 Appendix 1.1 Startup of Visual Basic® [Startup] 1) Click [Start] – [All Programs] – [Microsoft

Seite 64

App - 2 [Visual Basic® screen] 6) Code window2) Toolbox 1) Toolbar 3) Form window 4) Project window5) Properties window 1) Toolbar The commands

Seite 65

App - 3 [Display of Form window] Select the form module file from the Project window and click the [Form] button. [Display of Code window] Double

Seite 66 - H) error codes of

App - 4 Appendix 1.2 Outline Command For...Next statement Functions The flow control statement which repeats a series of statements for the d

Seite 67

App - 5 Explanation For the argument step, positive values and negative values can be designated. Depending on the designated value in the argu

Seite 68

1 - 6 1.3 Communication Protocol The MELSEC-Q Ethernet module described here supports two communication protocols, TCP/IP and UDP/IP. 1.3.1 Communic

Seite 69 - CHAPTER 5 ASSIGNMENT I

App - 6 Hex function Functions Returns a character string which indicates the designated value in hexadecimal. Format Hex(number) For an a

Seite 70 - MELSEC-Q

App - 7 If...Then...Else statement Functions The flow control statement which performs the execution with condition based on thevalue of an exp

Seite 71 - (Use connection 1)

App - 8 Caution Though the first syntax can describe several statements for one condition, it is necessaryto describe it in one line dividing with

Seite 72

App - 9 Appendix 1.3 Term Form A window which forms the basis of an application interface An application consists of at least one form. Control

Seite 73

App - 10 Appendix 1.4 Toolbox List When arranging a control to a form, the buttons on the toolbox can be used. Control Function Pointer Moves a

Seite 74

App - 11 The control that is not provided for the standard toolbox is called the ActiveX control. The custom control can add/delete a control usin

Seite 75

App - 12 Appendix 1.5 Toolbar List The following buttons are provided to easily call out frequently-used commands. Button Name Function Standar

Seite 76

App - 13 Button Name Function Start Executes the application that has been created at design. Break Cancels the execution of the program, and

Seite 77

App - 14 Appendix 1.6 Property List Property Description Action Operation to be executed by the OLE client ActiveContol Control with focus Activ

Seite 78

App - 15 Property Description Default Command button used by default DisplayType Sets an object display form. DownPicture Sets a picture to be

Seite 79

1 - 7 <Ethernet module and communication model> The following shows the software configuration of the Ethernet module corresponding to the &quo

Seite 80

App - 16 Property Description Instancing Sets the instance operation of the ActiveX class module. IntegralHeight Automatically changes a list he

Seite 81

App - 17 Property Description ObjectAcceptFormats Data format list that can be accepted in an object ObjectAcceptFormatsCount Number of factors i

Seite 82

App - 18 Property Description SizeMode Sets the display methods of a OLE container size or image when an object is in. SmallChange Amount of a s

Seite 83

App - 19 Appendix 1.7 Method List Method Description AddItem Adds items to the list box, grid, etc. Arrange Aligns windows and icons on the MDI

Seite 84

App - 20 Method Description ReadFromFile Reads an object from the data file created with the SaveToFile method. Refresh Updates a form or contro

Seite 85 - E71-1.VBP

App - 21 Appendix 1.8 Function List Function Description Abs Returns the absolute value of mathematical expression. Array Returns the variant va

Seite 86

App - 22 Function Description Exp Exponential function FileAttr Returns the file handle information of OS or the file mode. FileDateTime Returns

Seite 87

App - 23 Function Description IsObject Returns whether an object is actually referred by an expression or not. Join Returns the character string

Seite 88

App - 24 Function Description Rnd Generates a random number. Round Returns a numerical value rounded at the designated decimal point RTrim,RTrim

Seite 89

App - 25 Appendix 2 MX Component Appendix 2.1 Functions of MX Component The MX Component is used to access to the PLC CPU via various communicatio

Seite 90 - Complete the program

1 - 8 1.3.2 IP protocol (1) Role of IP IP is a network layer protocol which is processed by all devices connected to an IP network. The most importan

Seite 91

App - 26 (2) Substantial improvement in user's development efficiency The MX Component comes with the wizard type communication setting util

Seite 92

App - 27 (6) Read and write of PLC CPU clock data You can read and write the clock data of the PLC CPU connected to the DOS/V personal computer.

Seite 93

App - 28 (9) A wide variety of programming languages MX Component supports VBScript and VBA as well as Visual Basic® and Visual C++®. (a) Creati

Seite 94

App - 29 (b) VBA-driven data collection and monitoring function Programming using VBA (*1) allows Excel or Access functions to be utilized to cre

Seite 95

App - 30 Appendix 2.2 Function List The following shows the function list of the MX Component. (1) to (4) indicate the details of the functions us

Seite 96

App - 31 (1) Open (Open of communication line) (a) Function Opens a communication line. (b) Format Visual Basic®, Visual C++®, VBA: lRet = objec

Seite 97 - E71-2.VBP

App - 32 (3) ReadDeviceRandom (Random read of devices) (a) Usable ACT control Usable for all ACT controls. (b) Function Randomly reads devices

Seite 98

App - 33 (e) Device designation The following explains how to designate devices. (Example 1) When designating as follows (three device points) Wh

Seite 99

App - 34 (4) WriteDeviceRandom (Random write of devices) (a) Usable ACT control Usable for all ACT controls. (b) Function Randomly writes devi

Seite 100

App - 35 (e) Device designation The following explains how to designate devices. (Example 1) When designating as follows (three device points) Whe

Seite 101

1 - 9 1.3.3 TCP and UDP TCP and UDP are protocols which are processed by the devices and PCs on the both ends of communication (Transport layer). (1

Seite 102

App - 36 Appendix 2.3 Error code List The following explains the error codes to be returned by the ACT control and by the PLC CPU, intelligent fun

Seite 103 - Y70Y71Y72Y73Y74Y75Y76Y77

App - 37 Error code Description of error Corrective action 0x01801007 Designated CPU error Check the station No. designated at ActCpuType. Con

Seite 104

App - 38 Error code Description of error Corrective action 0x01802016 Station No. designation error The method does not support the operation fo

Seite 105

App - 39 Error code Description of error Corrective action 0x01808009 COM port handle error The handle of COM port cannot be acquired. The COM p

Seite 106

App - 40 Error code Description of error Corrective action 0x01808304 Insufficient size of the receive buffer The receive data is greater than t

Seite 107 - CPUS (PROCEDURE EXIST))

App - 41 Error code Description of error Corrective action 0x01808502 USB driver connection error The USB driver connection has failed. Complete

Seite 108

App - 42 Error code Description of error Corrective action 0x10000033 Designated device range error Review the contents of the designated devic

Seite 109

App - 43 Error code Description of error Corrective action 0x1000005 Size error The size designated in the read/write method is error. The read/

Seite 110

App - 44 (2) Error codes returned from PLC CPU, intelligent function module and network board. The following explains the error codes returned fr

Seite 111

App - 45 2) When using AJ71E71, AJ71QE71 If the lower two bytes error code that is occurred during the E71 and QE71 communications are not listed

Seite 113

1 - 10 (2) Comparison between TCP and UDP The request level for the network differs depending on the user application. However, it is difficult to c

Seite 114

App - 46 Appendix 3 Connecting GX Developer to PLC CPU via Ethernet This section describes how to operate GX Developer to access a PLC CPU via an

Seite 115

App - 47 1) Connect the GX Developer and Ethernet module to the Ethernet. 2) Click the [Online] [Transfer setup] menu. 3) Select "E

Seite 116

App - 48 Continued from the previous page 5) Select "Other station (Single network)". 6) Click the Connection test button to

Seite 117

App - 49 Appendix 4 Troubleshooting This section explains the contents of the errors that may occur during communications between the Ethernet mod

Seite 118

App - 50 Appendix 4.1 How to Check Errors Using LED Displays This section describes the errors that can be checked with the LED displays on the fr

Seite 119

App - 51 (From the previous page) LED name Status to check Cause/corrective action 5 [RD] [RD] LED stays off and data cannot be received. 1)

Seite 120

App - 52 Appendix 4.1.2 How to turn off COM.ERR. LED and to read/clear error information This section explains how to turn off the [COM.ERR.] LED

Seite 121 - <Abnormal completion>

App - 53 Appendix 4.2 How to Check an Error Through GX Developer The status of the various settings for the Ethernet module can be checked using t

Seite 122

App - 54 Appendix 4.2.1 Ethernet diagnostics [Purpose] The module status of the Ethernet module, parameter settings, communication status, error l

Seite 123 - <Receiving side>

App - 55 Appendix 4.2.2 System monitor The module status of an Ethernet module can be checked from the system monitor. (1) Checking the module s

Seite 124 - QJ71E71-100

1 - 11 1.4 MELSEC-Q Ethernet Module 1.4.1 Role of Ethernet module The Ethernet module supports the data communications between external devices and

Seite 125

App - 56 (2) Checking the LED on/off status and operation mode number on the H/W information screen of the diagnostic functions [Start Procedure

Seite 126

App - 57 Appendix 5 DEDICATED INSTRUCTIONS Dedicated instructions are used to simplify the programming for using the functions of the intelligent

Seite 127

App - 58 Appendix 5.2 OPEN Instruction This instruction establishes a connection (open processing) with an external device to perform the data com

Seite 128

App - 59 Control data Device Item Setting data Setting range Set by (*1) (S2)+0 Execution type/complete type • Designate which settings to us

Seite 129

App - 60 Functions (1) This instruction performs the open processing for a connection specified by (S1) for the module designated by Un. The sele

Seite 130

App - 61 Program example A program that opens the connection 1 for the TCP/IP communication (Active open): When the input/output signals of the Et

Seite 131

App - 62 Appendix 5.3 CLOSE Instruction This instruction disconnects (closes) a connection by which data was communicated with an external device.

Seite 132

App - 63 Functions (1) This instruction closes the connection specified by (S1) for the module designated by Un. (Disconnection) (2) Whether or

Seite 133

App - 64 Program example A program that closes the connection number 1: When the input/output signals of the Ethernet module are X/Y00 to X/Y1F

Seite 134

App - 65 Appendix 5.4 BUFSND Instruction This instruction sends data to an external device through thefixed buffer communication. Applicable devi

Seite 135

1 - 12 1.4.2 Outline of Ethernet module (1) Supporting the TCP/IP and UDP/IP communications The Ethernet module supports the TCP/IP and UDP/IP co

Seite 136

App - 66 Functions (1) This instruction sends the data designated by (S3) to the external device of the connection specified by (S1) for the modu

Seite 137

App - 67 Program example A program that sends data from the fixed buffer of the connection number 1: When the input/output signals of the Ethernet

Seite 138

App - 68 Appendix 5.5 BUFRCV Instruction This instruction reads data received from an external device through the fixed buffer communication. This

Seite 139

App - 69 Functions (1) This instruction reads receive data (for the fixed buffer communication) from the connection specified by (S1) for the mod

Seite 140

App - 70 Errors (1) When a dedicated instruction ends with an error, the abnormal completion signal, (D2) + 1, turns on and the error code is sto

Seite 142 - Execute the PING test!

Microsoft, Windows, Microsoft WindowsNT are registered trademarks of Microsoft Corporation in the United S

Seite 144

Ethernet course(Q-series)Mitsubishi Programmable Logic Controller Training ManualEthernet course(Q-series)Ethernet course(Q-series)Mitsubishi Program

Seite 145

2 - 1 CHAPTER 2 BEFORE USING ETHERNET MODULE 2.1 Two Data Codes The Ethernet module can exchange data with external devices using binary or ASCII co

Seite 146

2 - 2 (2) Communication using the ASCII code The Ethernet module sends/receives 1-byte data as data equivalent to two characters in the ASCII code.

Seite 147

2 - 3 2.2 Types of Data Communication Functions The Ethernet module has three types of communication functions: "Communication using MC protoco

Seite 148

2 - 4 (b) Reading/writing file in PLC CPU This function reads and writes files such as sequence program files or parameter files that are stored in

Seite 149

2 - 5 (3) External devices capable of exchanging data The communication using the MC protocol can be performed from the following external devices

Seite 150

2 - 6 2.2.2 Fixed buffer communication A PLC CPU can communicate with other PLC CPUs or a personal computer using the fixed buffers in the buffer me

Seite 151

2 - 7 As shown in the diagram below, set IP addresses and usage conditions (e.g. sending/receiving, with/without procedures) of external devices to r

Seite 152

A - 1 SAFETY PRECAUTIONS (Always read these instructions before the exercise.) When designing the system, always read the relevant manuals and gi

Seite 153

2 - 8 (4) Outline of data sending/receiving procedures Data sending/receiving is performed as shown in the following figure. (a) At TCP/IC communic

Seite 154

2 - 9 2.2.3 Communication using random access buffer A PLC CPU can communicate with a personal computer using the random access buffer in the buffer

Seite 155 - Version 6

2 - 10 (3) Outline of data sending/receiving procedures Data are sent or received as shown in the following figures. (a) TCP/IC communication PLC C

Seite 156 - 6) Code window

2 - 11 2.3 Open/Close Processing For data communication with external devices using the Ethernet module, a connection must be established (connection

Seite 157

2 - 12 (In TCP/IP communication) • The connection is established when the open processing is completed normally. • When the close processing perform

Seite 158 - For...Next statement

2 - 13 *1 For the open and close processing on the Ethernet module side shown below, there are two methods:performing from the PLC CPU and by the Et

Seite 159

2 - 14 (2) If the following 1) or 2) are set in the previously mentioned parameter settings, the open and close processing of the corresponding conn

Seite 160 - Hex function

2 - 15 (2) Open processing (a) The open processing is a processing which enables data communication with external devices. 1) In TCP/IP communicati

Seite 161 - If...Then...Else statement

2 - 16 (3) Close processing (a) The close processing is a processing which disables data communication with external devices. 1) In TCP/IP communic

Seite 162

2 - 17 2.3.1 Active open/close processing The Active open executes the connection processing to the external device, which TCP/IP connection is in t

Seite 163

A - 2 REVISIONS * The text number is given on the bottom left of this textbook. Print date * Textbook number Revision Jan., 2006 SH-080618ENG-A F

Seite 164

2 - 18 Open statusOpen ready status (closed)Closed statusInitial normal completion X19OPEN instructionOPEN instruction complete deviceOPEN instruct

Seite 165

2 - 19 2.3.2 Passive open/close processing The Passive open puts the open request (connection request by Active open) from an external device of the

Seite 166

2 - 20 (2) When "Do not wait for OPEN" is set in the operational settings The open and close processings are performed using the sequence

Seite 167

2 - 21 Open statusOpen ready status (closed)Closed statusInitial normal completion X19OPEN instructionOPEN instruction complete deviceOPEN instruct

Seite 168 - Appendix 1.6 Property List

2 - 22 2.3.3 UDP/IP open/close processing The open and close processing in UDP/IP is internal processing of the Ethernet module. The processing of t

Seite 169 - App - 15

2 - 23 Open statusOpen ready status (closed)Closed statusInitial normal completion X19OPEN instructionOPEN instruction complete deviceOPEN instructi

Seite 171 - App - 17

3 - 1 CHAPTER 3 SYSTEM CONFIGURATION 3.1 Applicable Systems The Ethernet modules can be used in systems to which the following descriptions apply.

Seite 172 - App - 18

3 - 2 3.2 Devices Required for Network Configuration This section explains the devices that are required to configure a network. Network installatio

Seite 173 - Appendix 1.7 Method List

3 - 3 (b) Connection using 10BASE-T Ethernet moduleExternal deviceTwisted pair cableHub* Up to 4 stages are allowed for cascade connection Use

Seite 174 - App - 20

A - 3 INTRODUCTION This textbook explains how to use the Ethernet module QJ71E71 of MELSEC-Q series and its programming. Use a personal computer app

Seite 176 - App - 22

4 - 1 CHAPTER 4 SPECIFICATIONS OF ETHERNET MODULE & SETTINGS AND PROCEDURES PRIOR TO OPERATION 4.1 Performance Specifications The following expla

Seite 177 - App - 23

4 - 2 *1 The e-mail transmission and reception function of the PLC CPU and the random access buffer communication function cannot be used together. O

Seite 178 - App - 24

4 - 3 4.2 Ethernet Module Function List This section shows a list of Ethernet module functions. (1) Basic functions of the Ethernet module The Eth

Seite 179 - Appendix 2 MX Component

4 - 4 (2) Additional functions of the Ethernet module The following table lists the additional functions of the Ethernet module that can be used. F

Seite 180 - Device status is checked

4 - 5 4.3 Settings and Procedures Prior to Starting the Operation The following shows the Ethernet module settings and a flow of the operation proce

Seite 181 - Access to clock data

4 - 6 Important (1) Do not write any data in the "System area" of the buffer memory of the intelligent function module. (2) Do not out

Seite 182

4 - 7 4.4 Components of the Ethernet Module This section shows the names of the Ethernet module components. Name Description 1) LED display Ref

Seite 183 - <Access>

4 - 8 4.5 Connecting to the Network The following explains how to connect the Ethernet module to the 10BASE-T/ 100BASE-TX network. <Operating pr

Seite 184

4 - 9 4.6 Settings from GX Developer To use the Ethernet module, parameters must be previously set from GX Developer. For the parameter settings of

Seite 185

A - 4 CONTENTS SAFETY PRECAUTIONS...

Seite 186

4 - 10 (2) "Network parameters Setting the number of MNET/10H Ethernet cards" Settings for the Ethernet module to use as a network module

Seite 187

4 - 11 (a) Operational settings Set the communication data code, the timing to start the OPEN processing, and the local station Ethernet module IP ad

Seite 188

4 - 12 (b) Open settings Set the protocols and the connection open systems for a data communication. Item Setting details Protocol Set the commun

Seite 189

4 - 13 (c) Router relay parameter (Routing information) This is the setting for the data communication with external devices via a router. The routi

Seite 190

4 - 14 4.7 Self-Diagnostic Tests 4.7.1 Self refrain test The self refrain test is used to check whether the Ethernet module transmits a test message

Seite 191 - App - 37

4 - 15 Continued from the previous page 4) The Network parameters Setting the number of MNET/10H Ethernet cards screen is displayed. 5) Se

Seite 192 - App - 38

4 - 16 (3) Writing the parameters to the PLC CPU The set parameters are written to the PLC CPU. For designating the connection destination, refer to

Seite 193 - App - 39

4 - 17 4.7.2 Hardware test The hardware test is performed to confirm that RAM and ROM of the Ethernet module are normal. The operation procedure of t

Seite 194 - App - 40

4 - 18 4.8 Mounting and Dismounting the Module This section explains the procedures when mounting/dismounting the Ethernet module. (1) Operation p

Seite 195 - App - 41

5 - 1 CHAPTER 5 ASSIGNMENT I (MC PROTOCOL COMMUNICATION BETWEEN PLC AND PLC CPU) In this assignment, the exercise of the MC protocol communication

Seite 196 - App - 42

A - 5 4.8 Mounting and Dismounting the Module... 4-18 C

Seite 197 - App - 43

5 - 2 (2) I/O assignment X0 to X3F Y40 to Y7FQX42(64 points)QY42P(64 points)Q64AD(16 points)QCPU(No.2)XA0XBFYA0YBFQ61P-A1(Power supply)QCPU(No.1)*Q6

Seite 198

5 - 3 (3) Exercise description Monitors and writes a device in the program using the MX Component. <Device read (Section 5.4)> <Device wri

Seite 199

5 - 4 5.2 Parameter Settings and TCP/IP Settings for PC The parameters of the Ethernet module on the PLC CPU side are set using the GX Developer bef

Seite 200

5 - 5 Continued from the previous page 4) Double-click "PLC parameter" from the project data list. 5) After the "Qn(H) Paramet

Seite 201

5 - 6 5.2.2 Network parameters setting the number of MNET/10H Ethernet cards Ethernet parameter setting is performed for connecting to Ethernet.

Seite 202

5 - 7 Continued from the previous page 6) Set the following contents, click the End button, and then close the "Ethernet operations" d

Seite 203 - Appendix 4 Troubleshooting

5 - 8 Continued from the previous page 11) Click the button. (Overwriting the project) 12) Set Drive/Path and Project name, then click the Sav

Seite 204

5 - 9 5.2.3 Transfer setup Transfer setup is performed to write a parameter to the PLC CPU. 1) Click the [Online] [Transfer setup] menu. 2) C

Seite 205 - H) of the buffer memory

5 - 10 5.2.4 Parameter write The set parameters are written to the PLC CPU. 1) Click . (Write to PLC) 2) Click the Param+Prog button on the &q

Seite 206

5 - 11 5.2.5 TCP/IP settings for PC TCP/IP settings for PC are performed. This textbook explains using a PLC operated with Microsoft® Windows® XP pr

Seite 207 - Send e-mail information

A - 6 8.2.1 Setting parameters with GX Developer... 8- 2 8.2.2 Se

Seite 208

5 - 12 Continued from the previous page 4) Select "Use the following IP address" and make the setting for the following contents. IP

Seite 209 - H, EEH …

5 - 13 5.3 Operation of MX Component This section explains the operation of the MX Component. This textbook explains the functions when creating app

Seite 210

5 - 14 Continued from the previous page 3) Click the Wizard button. 4) After the screen shown on the left appears, set "Logical station

Seite 211

5 - 15 Continued from the previous page 7) As the communication setting is performed, set the following contents and click the Next> button

Seite 212

5 - 16 5.3.2 Communication diagnostics Execute the communication diagnostics and confirm whether or not the logical station number is properly set.

Seite 213 - Control data

5 - 17 5.4 Visual Basic Program (Device Read) The contents of ON/OFF status for PLC CPU bit device X0 to X7 (eight points) and of word device D0 to

Seite 214

5 - 18 Private Sub cmdMonitor_Click() If tmrTime.Interval = 0 Then 'Confirm whether it is in process of monitoring or not

Seite 215 - Program example

5 - 19 'Execute the random read lRet = ActEasyIF1.ReadDeviceRandom(szDeviceList, lSize, lData(0)) If lRet <> 0 Then

Seite 216 - H : Normal completion

5 - 20 (1) Flowchart (a) cmdOpen_Click() (Operation by clicking the Open button) STARTIs the open normal?Open of communication line(Open())"C

Seite 217 - Connection

5 - 21 (b) cmdClose_Click() (Operation by clicking the Close button) STARTIs the close normal?Close of communication line(Close())"Communicati

Seite 218 - App - 64

A - 7 About Generic Terms and Abbreviations Unless otherwise stated, this textbook uses the following abbreviations and terms for the explanation of

Seite 219

5 - 22 (c) cmdMonitor_Click() (Operation by clicking the Monitor start button) STARTIs the timer operating?"Monitoring"StatusStart monito

Seite 220 - Send data length

5 - 23 (e) tmrTime_Timer() (Operation during monitoring) STARTStore the device to be monitoredto DevboxENDYesNoStore the device list toszDeviceList

Seite 221 - App - 67

5 - 24 5.4.2 Operation of demonstration machine The program is executed, and the device of PLC CPU is monitored. (1) Program screen The following i

Seite 222

5 - 25 Continued from the previous page 4) Click the Open button to open the communication line. When opening normally, "Communication line

Seite 223 - Receive data

5 - 26 (3) Check of device status of D0 to D4 The numerical value changed by the MX Component is checked in a program. (*1) *1 The following can be

Seite 224

5 - 27 Continued from the previous page 5) After the "Device write" screen appears, input any numerical value to "Setting value&q

Seite 225

5 - 28 Continued from the previous page 8) To end monitoring, click the Monitor stopbutton. 9) Click the Close button to close the communic

Seite 226

5 - 29 5.5 Visual Basic Program (Device Write) The contents of PLC CPU bit device Y70 to Y77 (eight points) and of word device D0 to D4 (five words)

Seite 227

5 - 30 Private Sub cmdMonitor_Click() Dim i As Integer 'Variable 1 for loop Dim j As Integer 'Variable 2 for loop

Seite 228

5 - 31 'Execute the random write lRet = ActEasyIF1.WriteDeviceRandom(szDeviceList, lSize, lData(0)) If lRet = 0 Then txt