2- 32
2. REPLACEMENT PROPOSAL FROM A-MOTION TO QDS-MOTION
4.3 Program Diversion Procedure in PLC CPU Side
4.3.1 Conversion procedure of a sequence project for QnUD(E)(H)CPU using GX Works2/
GX Developer
The following describes an example of the procedure for replacing a sequence project using
GX Developer. Always backup the project before the replacement.
(1) Conversion of sequence program created by SW3RNC-GSVE/SW2□-GSVE
1) After starting GX Works2, select "Start GX Developer" from the "Project" tab.
2) The following shows the conversion of a sequence program created by
SW3RNC-GSV/SW2□-GSV (GPPA file format).
After GX Developer is started, select "Import file" --> "Import from GPPA format file" from the
"Project" tab.
Caution 1: Storage location of an execution file
The execution file in the GPPA format is usually stored in the following folder.
• Folder structure
"C drive (route drive)" --> "GPP" --> "USR" --> "System name" --> "Machine name (folder which
includes the gppa.cnf file)"
Caution 2: Name of diversion source project
When name of diversion source project exceeds 8 characters, it can not be read.
Change the name so that the number of characters is within the limit and execute the conversion
operation.