Mitsubishi Electric A173UHCPU Spezifikationen Seite 96

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 202
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 95
2- 49
2. REPLACEMENT PROPOSAL FROM A-MOTION TO QDS-MOTION
The following shows the procedure for replacing devices in a motion side project using MT Developer2.
Always backup the project before the replacement of devices.
1) Start MT Developer2, and select "Replace Device Number Batch" from the "Find/Replace" tab.
2) Select "Replacing with specified K/F/G program range" and input "Replace From:/To:" and "Replace
With:" in "Device No.". Select "Check >> Execute".
1) Specify the end device from start device before conversion.
2) Specify start device after conversion.
3) Replace "M3840 to M4159" with device numbers of "M768 to M1087" by the same method as 2).
2)
1)
Seitenansicht 95
1 2 ... 91 92 93 94 95 96 97 98 99 100 101 ... 201 202

Kommentare zu diesen Handbüchern

Keine Kommentare